Summary
- Problem: Most heat pumps sold in DE/AT/NL since ~2013 have SG-Ready contacts; almost nothing drives them. Dynamic tariffs (mandatory offer in DE since Jan 2025; 573 negative-price hours on the German day-ahead market in 2025 per Bundesnetzagentur via the sources below) make hour-shifting worth real money — vendor blogs claim up to several hundred euros a year, unverified.
- Customer: Homeowners with a heat pump or electric boiler on a dynamic tariff (NL/DE/AT); the heat-pump installer who fits the box; energy advisors.
- Product: A 4-module DIN-rail box: ESP32, four dry-contact relays (two for SG-Ready states, two spare for boiler/pool/EV), local web UI, price fetch from day-ahead markets, optional surplus logic from a P1/Modbus energy meter, guard-rails (minimum run/off times per SG-Ready rules). €129–169 (estimate).
- Why now: Installers are asked about dynamic tariffs weekly and answer with a Shelly and a Home Assistant forum thread. Energy-manager systems cost "several hundred to over €1,000 plus a monthly fee" (Utopia). A €149 box that does one thing fills the hole.
- The ask: ~€70k to a certified first 1,000; installer pre-commitments carry a big share.
External market check (November 2026): LIKELY. SG-Ready is confirmed as a real certified German standard (BWP) supported by most EU heat-pump makers (NIBE, Viessmann, Vaillant). Installers and owners actively discuss wiring dynamic-tariff logic to SG-Ready with DIY tools (Shelly relay + Home Assistant, evcc, the Tibber app) on HaustechnikDialog and in the simon42 / evcc communities. Germany's BEG funding rules reportedly require a digital grid-control interface on new heat pumps from July 2027. Main risk: A cheap DIY substitute already exists (Shelly relay at roughly €30–40 plus free Home Assistant or evcc), and one forum voice called plain SG-Ready "not very useful" without extra conditions. The real market is installers wanting a no-fuss, no-cloud box to resell, which matches the pack's B2B kill question. As researched November 2026 by web search; verify before relying on it. Verdicts are a reading of the evidence found, not a forecast. Competitors and sources found: see the market check in the competition table.
Validate demand first
Do this before anything else in this pack: before the business plan, before you order a sample board, and long before you e-mail a factory (section 5). The classic first-time mistake is to source and build first and find out later that nobody wanted it. Hardware mistakes are slow and expensive to undo; 15–20 conversations are cheap.
The gate: this idea's kill question
Do 10 heat-pump installers agree to put it in their next installs at €149 after seeing a 10-minute demo of the price logic?
You pass this section when you can answer that question with evidence you collected yourself, not a guess: written answers from at least ten decision-makers who hold the budget, at least three of whom put something on paper: a signed letter of intent, a paid pilot, or a dated purchase order for the first units. Until then: no factory e-mail, no sample order, no firmware, no logo. If the answer is no, you have lost a few weeks and saved the rest.
Who you are looking for
The audience named in the idea: Homeowners with heat pumps or electric boilers on dynamic tariffs in NL/DE/AT; electricians who install heat pumps.
The problem as the pack states it: Most heat pumps sold in DE/AT/NL since ~2013 have SG-Ready contacts; almost nothing drives them. Dynamic tariffs (mandatory offer in DE since Jan 2025; 573 negative-price hours on the German day-ahead market in 2025 per Bundesnetzagentur via the sources below) make hour-shifting worth real money — vendor blogs claim up to several hundred euros a year, unverified.
Talk to the people who have the problem and the people who pay; in B2B they are often not the same person, and the one who pays decides.
Where to find them
Communities and associations where this audience actually talks, as far as we know them in November 2026. Confirm each is still active and read its rules on self-promotion before posting; most allow a genuine question about a problem and ban a pitch.
- HaustechnikDialog (DE) · haustechnikdialog.de/ — German heating installers and owners; hydronic balancing, heat pumps, legionella.
- Photovoltaikforum (DE) · photovoltaikforum.com/ — German PV, battery, heat-pump and dynamic-tariff owners.
- r/heatpumps · reddit.com/r/heatpumps/ — heat-pump owners and installers, EU and US.
- OpenEnergyMonitor community · community.openenergymonitor.org/ — open energy-monitoring builders; heat-pump monitoring is a major topic.
- Tweakers forum (NL) · gathering.tweakers.net/ — Dutch tech forum with active energy, domotica and smart-meter sections.
Beyond the named ones, the same four methods work for every idea on this site:
- Search for communities around the problem, not the product: forums, Facebook groups, Discord servers and newsletters in your own country for the terms in the audience line above. Many of the best groups are national and in the local language; a Dutch or German group beats a global English one for an EU launch.
- Trade associations and their regional meetings for the B2B audiences: one meeting puts twenty buyers in a room, and the association newsletter will often run a short survey for a member.
- LinkedIn: search people by the job titles in the audience line, message ten a day with one question (not a pitch), and ask for twenty minutes. Expect one in five to say yes.
- Your deposit list from the kill question and anyone who replied to the fake door: those are the first interviews, not the last.
The plan: 15–20 conversations, then a fake door
- 15–20 real conversations (ten budget-holders and ten users), fifteen minutes each, using the script below. Before writing a line of code or ordering a board. Write up each one the same day: the problem in their words, what they do today, what it costs them, what they said when you named the price.
- A fake door. One page: the pitch as the headline, a rendered image or a photo of a cardboard mock-up, the price (€129–169, the pack's estimate), and one button. For a business buyer the button is "request a pilot" that leads to a short form and a letter of intent.
- Send it to everyone you interviewed and post it, with the problem question first, in the communities above. Run it for two to four weeks.
- Count against the kill question. Then decide: go, change the idea, or stop.
Interview script (fifteen minutes, problem first)
Ask, then be quiet. Do not describe the product until question 5; if you pitch first you will only hear politeness.
Thanks for the time. I am looking into how homeowners with heat pumps or electric boilers on dynamic tariffs in NL/DE/AT deal with [the problem in their words]; I have not built anything yet and I am trying to find out whether it is worth building.
1. Does your heat pump react to electricity prices or solar surplus today, and if not, what have you tried?
2. What do you do about it today, and what does that cost you in money or time per month?
3. What have you already tried or bought, and why did you stop using it?
4. If this went away tomorrow, what would change for you? (If the answer is "not much", you have your answer.)
5. [Only now describe it in one sentence:] A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account. On a scale of one to ten, how likely would you be to buy that at €129–169, and what would make it a ten?
6. Who else should I talk to about this? (Ask for two names.)
Close: "If I build this, can I come back to you with a prototype?" A yes with a calendar date is worth more than any compliment.
Pre-order / pilot message (forum post or direct message)
Subject: SG-Ready Price Switch: looking for 3 pilot sites before we build it
I am [your name], [your background]. We are considering building a SG-Ready Price Switch: A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account. Before we spend money on tooling I want to find out whether this solves a real problem for homeowners with heat pumps or electric boilers on dynamic tariffs in NL/DE/AT.
If it would, I am looking for three pilot customers willing to sign a short letter of intent now and pay €129–169 per unit for the first batch, delivered in [month]. The LOI is non-binding on the price; it tells me the problem is real.
Two questions, no pitch: how do you handle this today, and what would make you say no to the above? Twenty minutes on a call this week, or a reply here, both help.
Reading the signal
| Real signal | False positive |
|---|---|
| A refundable deposit, a signed LOI, a paid pilot, a calendar invite for the prototype | "Sounds cool", "I would totally buy that", likes and upvotes |
| They describe the problem unprompted and in detail, with numbers | They agree with your description of the problem |
| They have already paid for a workaround (a product, a service, their own time) | They have never tried anything and are not bothered |
| Landing-page conversion to deposit or form above the pack's pass mark, from cold traffic | Conversion from friends, family and your own network |
| A named budget and a named decision-maker (B2B) | An enthusiastic user who cannot buy |
Go / no-go
- Go to section 3 (business plan) and section 4 (start kit) when the kill question above is met by your own numbers, you have 15–20 written-up conversations, and at least one real signal from the left column per segment you plan to sell to. Only then does section 5 (Who to contact) apply.
- Change the idea when the problem is real but the price, the buyer or the form factor in the pitch is wrong: the interviews will tell you which. Rewrite the pitch and run the fake door again; this is normal and costs a week.
- Stop when the kill question fails on honest numbers, or when nobody you talked to has paid for a workaround. Pick another idea on this site; the boards in the start kit are not wasted, only unused.
The full worksheet, with how to define the segment and run the fake door, is in the playbook → validate demand.
Business plan
Problem & customer
SG-Ready is a two-contact interface: four states (blocked, normal, recommended-on, forced-on). The heat pump decides what each state does; the signal source is "whatever closes the contact". Today that is a PV inverter's relay (surplus only) or a hobbyist Shelly driven by Home Assistant/evcc with Tibber/aWATTar prices. Energy-management systems from inverter brands are expensive and brand-locked.
- Who pays: the homeowner (through the installer's invoice, or directly online).
- Who installs: the electrician/heat-pump installer. The box must take 10 minutes: DIN clip, 230 V in, two wires to SG-Ready, WiFi onboarding from the phone.
- Who uses: nobody, after setup. It should be boring. A local web page shows "why the pump is on now".
Market size (estimates — check)
- TAM: heat pumps installed in DE (~2M+), NL (~1M incl. hybrids), AT (~0.5M), plus electric boilers and hot-water heat pumps (millions). Say 4M SG-Ready-capable devices in the three countries → at €149 €600M theoretical.
- SAM (owners on or moving to dynamic tariffs with a smart meter — the bottleneck in DE): 10–15% over the next 3 years → 400–600k → €60–90M.
- SOM (3 yrs): 2% of SAM via installers → 8–12k units. Year 1: 1,000–2,000.
Competition (2 searches)
| Alternative | What it is | Why we still win |
|---|---|---|
| Do nothing (SG-Ready unused) | The default | Our box pays back in one winter if the vendor claims are half right |
| Shelly relay + Home Assistant/evcc/openHAB + Tibber/aWATTar price integration | ~€25 + a hobby | Needs a server, a hobbyist and maintenance; installers will not support it |
| Inverter-brand energy managers (Solarwatt Manager, SMA Home Manager, Fronius, etc.) with SG-Ready output | €300–1,000+, brand-locked, mostly surplus-driven | We are brand-agnostic, price-driven and €149 |
| Heat-pump-brand dynamic-tariff features (e.g. iDM dynamic-tariff control, Viessmann/Vaillant apps with Tibber) | Built-in for new pumps of some brands | Installed base of older pumps is ours; also boilers, pool pumps |
| Reduxi-type HEMS with EVU contact control | Full HEMS with subscription-ish pricing | Overkill for "just the heat pump" |
| Smart-dog / solar-dog hobby HEMS | Niche DIY | Same as HA |
Wedge: installer-friendly, brand-agnostic, no cloud account, one job. The spare relays make it a "cheap-hour box" for the boiler and the pool pump too.
External market check
Competitors, demand signals and price comparables found by web search in November 2026. Sources are named as found and not linked; as researched November 2026 by web search; verify before relying on it. Verdicts are a reading of the evidence found, not a forecast.
| Who / source | What it is | What it tells us |
|---|---|---|
| SG-Ready standard (BWP), supported by NIBE, Viessmann, Vaillant and most EU makers | The interface the box drives | Real and widespread |
| HaustechnikDialog, simon42 and evcc community threads | Installers and owners wiring tariff logic to SG-Ready with Shelly + Home Assistant, evcc, Tibber | Demand signal and the DIY substitute at once |
| Shelly relay (roughly €30–40) + Home Assistant / evcc | Free-software DIY route | The cheap substitute to beat on simplicity |
| BEG funding rules (reported) | Digital grid-control interface required on new heat pumps from July 2027 | Regulatory tailwind; verify the wording |
Verdict as researched: LIKELY. Main risk: A cheap DIY substitute already exists (Shelly relay at roughly €30–40 plus free Home Assistant or evcc), and one forum voice called plain SG-Ready "not very useful" without extra conditions. The real market is installers wanting a no-fuss, no-cloud box to resell, which matches the pack's B2B kill question.
Product & value proposition
- 4 TE DIN-rail enclosure, 230 V AC input with an internal PSU (or 24 V DC SKU), ESP32-C6/S3, four relays with dry contacts (rated for control circuits, e.g. 2 A 30 V DC / 230 V AC 2 A — spec per relay datasheet), two digital inputs (inverter surplus contact, pump feedback), RS-485 for Modbus energy meters (optional).
- Logic: day-ahead price bands (cheapest N hours, threshold, percentile), SG-Ready state mapping with mandatory guard-rails (state 1 blocked max 2 h, 10-minute re-activation lock per the sources), surplus mode from P1/Modbus, schedules, holiday mode.
- Local web UI; no account; optional MQTT; signed OTA from your server.
- Pricing (estimates): €149 (€129 installer net), €39 Modbus meter add-on, €199 pro SKU with 24 V DC and 2 extra relays.
Unit economics (estimates, EUR per unit)
| Item | 1k | 5k |
|---|---|---|
| Electronics BOM (ESP32-C6 module €2.5, 4 relays €4, relay drivers + opto inputs €1.5, AC/DC 3.3/5 V module 3 W €3.5, RS-485 €0.8, terminals/screw blocks €3, PCB €1.5) | 16.8 | 14.0 |
| PCBA + test (hipot on mains side) | 3.5 | 2.4 |
| Enclosure (standard 4 TE DIN housing, printed label) | 3.0 | 2.2 |
| Packaging + leaflet + QR | 1.5 | 1.1 |
| Freight + duty to EU | 1.5 | 0.8 |
| Certification amortised (€22k incl. LVD) | 22.0 | 4.4 |
| Landed cost | 48.3 | 24.9 |
| Net price installer channel (€129 ex VAT) | 129 | 129 |
| Gross margin installer | €81 (63%) | €104 (81%) |
| D2C (€149 incl. 19% VAT → €125) less €8 fulfilment | €69 (59%) | €92 (79%) |
Mains in a DIN box means LVD testing and creepage/clearance discipline — budget it, do not skimp.
Go-to-market
First 100 customers: 10 heat-pump installers (via SHK-Innung lists, Haustechnikdialog, the Dutch installer forums, local Facebook installer groups) get a 10-minute demo and two boxes each at cost. Homeowners on Photovoltaikforum, Haustechnikdialog, Tweakers, akkudoktor forum. One YouTube explainer of the price logic.
Then scale: wholesalers (electrical wholesalers like the big German/Dutch ones — search), heat-pump distributors, dynamic-tariff retailers (bundle), energy advisors, PV installers, Amazon for the DIY tail.
12-month plan
- Q1: works-like on StamPLC + Unit 4Relay in a DIN base; price logic; 10 installer demos; two pilots in real homes through a winter month.
- Q2: own PCB (mains PSU, relays, isolation), DIN enclosure, 50-unit EVT with installers; Modbus meter add-on.
- Q3: certification (RED + LVD + EMC), 1,000 production; installer onboarding kit.
- Q4: wholesaler listing, 24 V pro SKU, retailer bundle talks.
Team: embedded engineer (full), power/safety-aware hardware engineer (half), founder with installer network, a part-time technical writer for the installer manual. Shenzhen partner for PCBA (with hipot testing) and DIN enclosure.
Funding to first 1,000 (estimate): landed hardware excl. cert €27k + certification €22k + tooling (label/enclosure minor) €2k + pilots €4k + 6 months team €45k + installer marketing €6k = ≈€106k; installer pre-orders (300 × €129 = €39k) reduce the external need to ≈€60–70k. Route: installer pre-orders + bootstrap; energy-efficiency grants (DE/NL have installer-innovation and flexibility programmes — search); angel if a tariff retailer wants a bundle.
Top risks
| Risk | Mitigation |
|---|---|
| Regulatory/safety: mains in a DIN box; relay contacts on a heat pump's low-voltage input | Only dry contacts to SG-Ready; LVD testing; clear installer-only labelling; consider a 24 V DC-only SKU first to defer LVD |
| Technical: every heat pump maps SG-Ready states differently | Installer wizard with brand presets built from pilots; conservative defaults (state 3 "recommended" only) |
| Market: heat-pump brands add dynamic tariffs natively | Installed base of older units is large; add boilers/pool/EV; be the cheap generic layer |
| Commercial: damaging a heat pump via wrong signals | Guard-rails hard-coded (max block time, min re-activation lock); liability insurance; installer sign-off |
| Supply: relay quality | Branded relays (Omron/Hongfa-class), incoming inspection |
Start kit
Boards to start from
| Board | Link | Contributes | Files (catalogue) | Licence note |
|---|---|---|---|---|
| M5Stack StamPLC (K141) | gongbans.com/db/m5stack-stamplc.html | DIN-rail PLC-style controller for the works-like prototype | enclosure/structure only | Finished product for prototypes; own PCB for production |
| M5Stack Base DIN (M132) | gongbans.com/db/m5stack-base-din.html | DIN-rail mounting reference and form factor | enclosure/structure only | Mechanical reference |
| M5Stack Unit 4Relay (U097) | gongbans.com/db/m5stack-unit-4relay.html | Four relays for the prototype | enclosure/structure only | Module for prototypes |
| Espressif esp32-c6-devkitc-1 | gongbans.com/db/espressif-esp32-c6-devkitc-1.html | WiFi 6 MCU reference for the re-spin | reference design files per catalogue (no schematic listed in this row) | Espressif reference terms — check |
Catalogue honesty: none of these four rows publishes electronics files; this product is "prototype on modules, design your own board". The relay ratings of Unit 4Relay are not in the catalogue — check M5 docs before switching anything real.
Block diagram
230 V AC ──► isolated AC/DC 3.3/5 V module ──► ESP32-C6 (WiFi)
ESP32 ──► relay drivers ──► 4× relays (dry contacts) ──► SG-Ready 1/2, boiler, spare
ESP32 ◄── 2× opto-isolated inputs (inverter surplus contact, feedback)
ESP32 ◄──► RS-485 (Modbus energy meter, optional)
WiFi ──► your price proxy (day-ahead by bidding zone) ; local web UI ; MQTT optional
DIN 4 TE housing; terminals top/bottom; status LEDs on the front
Engineering gap: mains isolation/creepage, relay sequencing with guard-rails, installer wizard with brand presets, and the price proxy (shared with the Tariff Lamp).
Starter BOM (estimates)
| Part | Est. @1k | Notes |
|---|---|---|
| ESP32-C6-WROOM-1 | €2.5 | Pre-certified |
| 4× relays 5 V coil, 2–5 A contacts (branded) | €4 | Pick a type with a safety file (UL/ENEC) |
| Relay drivers (ULN2003-class) + flyback | €0.5 | |
| Isolated AC/DC module 3 W (certified, EN 62368-1 file) | €3.5 | Buy a certified module; do not design the flyback yourself at this volume |
| Opto inputs ×2, RS-485 transceiver | €1.5 | |
| Screw terminals (pluggable), DIN 4 TE housing | €6 | Standard housings from several makers |
| PCB 2-layer with creepage slots | €1.5 |
Firmware/software starting point
- ESP-IDF on ESP32-C6 (or ESPHome for pilots — relays, inputs, web server exist).
- Price data: ENTSO-E Transparency Platform API; reuse the Tariff Lamp proxy.
- Surplus/metering: Modbus RTU libraries exist for ESP32; P1 readers via local API (HomeWizard — search).
- Logic references: evcc (open-source energy management with heat-pump/SG-Ready support in its docs) is worth reading for state handling; do not copy code without checking its licence.
- Brand mapping: build from pilots; the German heat-pump association (BWP) SG-Ready database lists compatible pumps — search.
12-week build plan
| Weeks | Gate | Exit criteria |
|---|---|---|
| 1–2 | Validate — StamPLC + Unit 4Relay + Base DIN, price logic in ESPHome/ESP-IDF, 10-minute demo video; 10 installer calls | ≥10 installers agree to fit it on their next installs at €149 (or ≥5 sign a pre-order) |
| 3–5 | Works-like — 5 prototypes in real homes with 3 heat-pump brands; guard-rails; local UI | No unsafe states; pumps respond as expected; owners see price-shifted operation in logs |
| 6–8 | Looks-like + EVT — own PCB rev A with certified PSU module, DIN housing, 30 units; hipot test | Passes 3 kV hipot; creepage per EN 62368-1; relay sequencing verified |
| 9–10 | DVT + pre-compliance — rev B, EMC pre-scan, LVD review with the lab, EN 18031 checklist, installer manual v1 | No fails; manual reviewed by 2 installers |
| 11–12 | Pilot batch — 50 units with 10 installers; support line | ≤2 failures; installers report <15 min install; brand presets for ≥6 pumps |
Certification checklist (EU)
- CE — RED (WiFi): EN 300 328 via module, EN 301 489-1/-17; because it is radio equipment, RED article 3.1(a) covers safety — the lab will test to EN 62368-1 (or EN 61010/EN 60730-type standards depending on how you classify a control device — ask the lab) for the mains part: €10–15k. A 24 V DC-only first SKU cuts this substantially.
- EN 18031-1 (connected): self-assess; keep the web UI password-protected, no cloud account: €2–4k.
- CRA: SBOM, signed OTA, disclosure contact; update support for the box's life (10 years is realistic in a fuse cabinet — plan it).
- RoHS, WEEE (B2B/consumer), REACH, packaging.
- No battery, no personal data beyond consumption (GDPR note in manual).
- Total estimate: €15–22k (mains SKU).
Validation toolkit
- Kill question: Do 10 heat-pump installers agree to put it in their next installs at €149 after seeing a 10-minute demo of the price logic? Cheapest experiment: StamPLC demo rig + a laptop + 10 coffees.
- Interview script (5): 1) How many of your customers ask about dynamic tariffs, and what do you tell them? 2) Which heat-pump brands do you install; what do their SG-Ready states do? 3) What do you use today when a customer wants surplus/price control — and who supports it afterwards? 4) What must the box have for you to fit it in 15 minutes (terminals, wizard, docs)? 5) €129 net to you, €149 to the customer — margin enough, or do you want to rent it?
- Landing page: Headline: "Run your heat pump when electricity is cheap. Automatically." Bullets: "Closes the SG-Ready contact on cheap hours and solar surplus — no cloud account." / "DIN-rail, installed by your electrician in 15 minutes." / "Four relays: heat pump, boiler, pool, whatever is next."
- Pre-order pass: ≥10 installers pre-order ≥3 units each (≥30 units) within 6 weeks.
First production checklist
- Samples: 5 PCBAs from an assembler that does hipot and ICT; golden sample with label and sealed screws.
- DFM: creepage slots, terminal torque, housing clip, LED light pipes.
- MOQ: PCBA 500; housings 500 from a standard maker; PSU modules 1k reel.
- QC/AQL: Z1.4 II, AQL 0.65 major (mains) / 2.5 minor; 100% hipot + relay click test + WiFi join.
- Packaging: installer-friendly box with wiring diagram on the lid; EU DoC + WEEE.
- Incoterms: FOB Shenzhen sea; pilot by air DAP.
Who to contact
On file: 2 board publishers (M5Stack and Espressif). Only useful once section 2 (validate demand) has passed. Everything below comes from gongban.db, the directory behind this site. It names the companies that publish the boards this idea is built from, the manufacturers on file, and directory entries in the same product category. None of it is a verified supplier relationship for this specific idea: nobody has quoted it yet. Company websites only; no personal contacts are published.
Board publishers (direct)
- M5Stack — community / maker brand; 274 boards in the catalogue; files via M5Stack M5_Hardware repo · github.com/m5stack/M5_Hardware. Boards used here: M5Stack StamPLC (K141) (DIN-rail PLC-style controller core); M5Stack Base DIN (M132) (DIN-rail base reference); M5Stack Unit 4Relay (U097) (four dry-contact relays). What to ask for: sample units of the SKUs above, unit pricing at 100 / 500 / 1,000, whether a customised variant is possible (and its NRE and MOQ), and the module's radio test reports if any.
- Espressif — chip house; 48 boards in the catalogue; files via Espressif esp-dev-kits (GitHub) · github.com/espressif/esp-dev-kits. Boards used here: Espressif esp32-c6-devkitc-1 (WiFi 6 MCU for the re-spin). What to ask for: sample units of the SKUs above, unit pricing at 100 / 500 / 1,000, whether a customised variant is possible (and its NRE and MOQ), and the module's radio test reports if any.
Manufacturing (PCBA / EMS) on file
- Kingbrother / King Brother Technology · global.kingbrother.com/ — PCB fab + EMS; see the Kingbrother SOM page on this site.
- Foxlink (SZ) (正崴精密工业(深圳)有限公司) · foxconn.com — PCBA + cable assembly EMS: Cable assembly; PCBA; connector; OEM for major electronics brands.
Also in the directory (category match, not idea-specific)
Companies in the gongban.db solution-house directory whose product category overlaps this idea. They were matched on the idea's tags, not on this design; none has seen it.
- Linkage Technology (深圳市联控智能科技有限公司) · linkage-tech.com — Smart meter / energy IoT solution house: Smart energy meter; sub-metering IoT; NB-IoT / LoRa; OEM/ODM. (Smart-metering / energy IoT)
- Tuya Smart (涂鸦智能股份有限公司) · tuya.com — IoT platform + module solution house: WiFi/BT/Zigbee/BLE Mesh modules; 500+ product smart-home gongbans; global OEM APP. (Smart-home modules and app platform)
- Tuya Smart Module (涂鸦智能模组部门) · developer.tuya.com — WiFi/BT/Zigbee smart home modules: CBU / WBR3 / BT3L modules; Alexa/Google certified; volume IoT OEM. (Smart-home modules and app platform)
- AI-Thinker (安信可科技(深圳)有限公司) · ai-thinker.com — ESP8266 / ESP32 module OEM: ESP-01; ESP32-CAM; A9 GSM modules; massive community. (ESP32 / ESP8266 modules)
MOQ and landed cost
gongban.db holds no MOQ, unit-price or tariff data for these companies, so none is shown. Get the numbers from the quote (the e-mail below asks for them) and run them through the landed-cost worksheet in the playbook. The starter BOM in the start kit section is an estimate, not a quote.
Outreach e-mail, ready to send
Fill in the [brackets], keep it short, and send it to the sales or "contact us" address on the company's own website. The Chinese version is the same letter; sending both in one mail is normal. How to read the reply: playbook → the first quote.
A. To a board publisher — samples and volume price (send to the sales / "contact us" address on the M5Stack and Espressif websites)
Subject: Sample order and volume pricing — M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1 — for a SG-Ready Price Switch
Hello [company] sales team,
I am [your name], founder of [your company] in [country]. We are developing a SG-Ready Price Switch: A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account. The design is built around your M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1.
Could you please send:
1. Price and lead time for [10] sample units of each: M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1.
2. Unit pricing at 100 / 500 / 1,000 pieces, EXW Shenzhen and DDP [your city], including packaging.
3. Whether a customised variant is possible (our enclosure, connector, or firmware pre-loaded), with the NRE and MOQ for it.
4. Radio test reports or module certification documents, if available, so we can plan EU (CE/RED) certification.
5. Payment terms and accepted methods for a first order.
We can share our block diagram and target quantities under NDA if that helps.
Best regards,
[your name] · [your company] · [website] · [phone / WhatsApp]
A. 中文版
主题:样品订购及批量报价 — M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1 — 用于SG-Ready Price Switch
[公司]销售团队,您好:
我是[姓名],[国家][公司]的创始人。我们正在开发一款SG-Ready Price Switch:A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account。产品设计基于贵司的M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1。
请提供以下信息:
1. 各[10]片样品的单价和交期:M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1。
2. 100 / 500 / 1,000 片的批量单价(深圳EXW及DDP到[城市]),含包装。
3. 是否可以定制(外壳、接口或预烧录固件),以及定制的NRE费用和最小起订量(MOQ)。
4. 如有,请提供射频测试报告或模组认证文件,以便我们规划欧盟CE/RED认证。
5. 首单的付款方式和条件。
如有需要,我们可在签署NDA后提供框图和目标数量。
祝好,
[姓名] · [公司] · [网站] · [电话 / WhatsApp]
B. To a PCBA / EMS house — quote from the open design files (send to Kingbrother, Foxlink or any assembler you vet; see the playbook)
Subject: PCBA quote from open design files — SG-Ready Price Switch, [50] prototypes + [500] production units
Hello [company] sales team,
I am [your name], founder of [your company] in [country]. We are building a SG-Ready Price Switch: A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account. The design starts from published open-hardware files (M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1; schematic, PCB and BOM available) with our own modifications.
Could you quote:
1. PCB fabrication + SMT assembly for [50] prototype units and [500 / 1,000] production units, including component sourcing (we provide the BOM with manufacturer part numbers).
2. NRE, stencil and test-fixture costs, and your DFM review fee if any.
3. Lead time from file approval to shipment, and your QC / functional-test process.
4. Box build (enclosure, cable, packaging) if you offer it.
5. Terms: EXW / FOB Shenzhen or DDP [your city]; payment terms for a first order.
Design files: [link to Gerber, BOM and pick-and-place files].
Best regards,
[your name] · [your company] · [website] · [phone / WhatsApp]
B. 中文版
主题:基于开源设计文件的PCBA报价 — SG-Ready Price Switch,[50]台样机 + [500]台量产
[公司]销售团队,您好:
我是[姓名],[国家][公司]的创始人。我们正在开发一款SG-Ready Price Switch:A DIN-rail box that closes a heat pump's SG-Ready or boiler contact — and up to four relays — when the hourly electricity price or your solar surplus says so, with no cloud account。设计基于已公开的开源硬件文件(M5Stack StamPLC (K141), M5Stack Base DIN (M132), M5Stack Unit 4Relay (U097), Espressif esp32-c6-devkitc-1;含原理图、PCB和BOM),并做了我们自己的修改。
请报价:
1. [50]台样机和[500 / 1,000]台量产的PCB制板+SMT贴片,含元器件采购(我们提供带厂商料号的BOM)。
2. NRE、钢网和测试治具费用,以及DFM评审费用(如有)。
3. 从文件确认到出货的交期,以及贵司的QC/功能测试流程。
4. 如可提供,整机组装(外壳、线材、包装)报价。
5. 贸易条款:深圳EXW/FOB或DDP到[城市];首单付款条件。
设计文件:[Gerber、BOM和坐标文件链接]。
祝好,
[姓名] · [公司] · [网站] · [电话 / WhatsApp]
Next steps (this week)
- Order StamPLC, Base DIN and Unit 4Relay; wire a price-logic demo (ENTSO-E day-ahead, cheapest 6 hours → relay) and film the 10-minute demo.
- List 20 heat-pump installers within an hour's drive; book 10 demos.
- Ask two labs how they would classify a DIN-rail WiFi relay box (EN 62368-1 vs EN 60730/61010) and whether a 24 V DC-only SKU would skip the mains tests.