Concept, not a product. Concept generated by the GONGBANS inventor from the public catalogue, then expanded into a start pack. Not a product, not validated; every number (market, BOM, price, effort, certification cost) is a rough estimate to be checked, not a quote. Check each board's licence before commercial use. Not legal, tax or investment advice.

New here? Start here → explains what a gongban is, the four steps and the first-timer mistakes. Come back to this pack afterwards.

Effort (estimate)12–16 team-weeks
Unit BOM (estimate)€35–55
Price (estimate)€199 (sale) / 29 per week (rental)
External market checkLikely
Boards referenced4 catalogue boards

Order of operations: read the summary, then validate demand (section 2) with real customers before you touch the start kit or e-mail anyone in Who to contact (section 5). New to hardware? The zero-experience founder playbook covers validation, samples, the first quote, CE/FCC, customs and fulfilment for all 50 ideas.

1 · Summary · the one-page version

Summary

  • Problem: New flat-pack furniture, fresh laminate and a renovated flat smell — and people worry about formaldehyde. The German guideline value is 0.1 ppm (≈ 124 µg/m³, UBA Richtwert I 0.1 mg/m³); a lab measurement costs €150–250 per room, a consumer meter is €20–120 of unknown accuracy. People need an answer for one week, not an instrument for life.
  • Customer: Furniture and flooring retailers (loan units at the till), real-estate agents and property managers (hand-over kit), and parents setting up a nursery. The retailer or agent pays and lends; the household uses. Consumer sale is the secondary channel.
  • Product: A rugged handheld with an electrochemical HCHO sensor, a BME680-class VOC/T/RH sensor and an NDIR CO2 sensor, 7-day logging, and a "move-in report" PDF via the phone. Sold at €199, rented at €29/week; the fleet model: 5 loan units per store, annual recalibration as a service (estimates).
  • Why now: Indoor-air awareness is mainstream, formaldehyde in furniture is a recurring consumer-press topic, and open sensor boards plus an off-the-shelf handheld dev kit make the prototype a two-week job. The gap is not the sensor — it is the calibration and the rental/report workflow.
  • The ask: ~€85k to 1,000 units; three furniture retailers running loan fleets first, then a crowdfunding/B2C wave once the report format proves itself.

External market check (November 2026): LIKELY. Direct-reading formaldehyde and VOC meter rentals exist (Extech VFM200, PCE meters) but are aimed at professionals, not consumer-facing retailer loan units; no furniture or flooring retailer loan-at-the-till programme was found, matching the pitch's channel angle. A pricier lab-analysed service (Wellbuild Lab, $395–525 a week) confirms willingness to pay at a much higher price point. Main risk: No evidence yet that retailers want to run a loan-unit programme; that channel is the actual kill question and is unverified. As researched November 2026 by web search; verify before relying on it. Verdicts are a reading of the evidence found, not a forecast. Competitors and sources found: see the market check in the competition table.

2 · Validate demand · before anything else

Validate demand first

Do this before anything else in this pack: before the business plan, before you order a sample board, and long before you e-mail a factory (section 5). The classic first-time mistake is to source and build first and find out later that nobody wanted it. Hardware mistakes are slow and expensive to undo; 15–20 conversations are cheap.

The gate: this idea's kill question

Will 3 furniture retailers put 5 loan units each at the till for a month, and do customers borrow them?

You pass this section when you can answer that question with evidence you collected yourself, not a guess: a fake-door landing page that furniture and flooring retailers, real-estate agents, parents with nurseries actually visited, with a measured conversion to a waitlist or refundable deposit, plus the interview notes behind it. Until then: no factory e-mail, no sample order, no firmware, no logo. If the answer is no, you have lost a few weeks and saved the rest.

Who you are looking for

The audience named in the idea: Furniture and flooring retailers (loan units), real-estate agents, parents with nurseries; rental platforms.

The problem as the pack states it: New flat-pack furniture, fresh laminate and a renovated flat smell — and people worry about formaldehyde. The German guideline value is 0.1 ppm (≈ 124 µg/m³, UBA Richtwert I 0.1 mg/m³); a lab measurement costs €150–250 per room, a consumer meter is €20–120 of unknown accuracy. People need an answer for one week, not an instrument for life.

Talk to the people who have the problem and the people who pay; in B2B they are often not the same person, and the one who pays decides.

Where to find them

Communities and associations where this audience actually talks, as far as we know them in November 2026. Confirm each is still active and read its rules on self-promotion before posting; most allow a genuine question about a problem and ban a pitch.

Beyond the named ones, the same four methods work for every idea on this site:

  • Search for communities around the problem, not the product: forums, Facebook groups, Discord servers and newsletters in your own country for the terms in the audience line above. Many of the best groups are national and in the local language; a Dutch or German group beats a global English one for an EU launch.
  • Trade associations and their regional meetings for the B2B audiences: one meeting puts twenty buyers in a room, and the association newsletter will often run a short survey for a member.
  • LinkedIn: search people by the job titles in the audience line, message ten a day with one question (not a pitch), and ask for twenty minutes. Expect one in five to say yes.
  • Your deposit list from the kill question and anyone who replied to the fake door: those are the first interviews, not the last.

The plan: 15–20 conversations, then a fake door

  1. 15–20 real conversations (twenty people from the audience line), fifteen minutes each, using the script below. Before writing a line of code or ordering a board. Write up each one the same day: the problem in their words, what they do today, what it costs them, what they said when you named the price.
  2. A fake door. One page: the pitch as the headline, a rendered image or a photo of a cardboard mock-up, the price (€199 (sale) / 29 per week (rental), the pack's estimate), and one button. For a consumer the button takes a refundable deposit or a waitlist e-mail; a deposit is worth ten e-mails.
  3. Send it to everyone you interviewed and post it, with the problem question first, in the communities above. Run it for two to four weeks.
  4. Count against the kill question. Then decide: go, change the idea, or stop.

Interview script (fifteen minutes, problem first)

Ask, then be quiet. Do not describe the product until question 5; if you pitch first you will only hear politeness.

Pre-order / pilot message (forum post or direct message)

Reading the signal

Real signalFalse positive
A refundable deposit, a signed LOI, a paid pilot, a calendar invite for the prototype"Sounds cool", "I would totally buy that", likes and upvotes
They describe the problem unprompted and in detail, with numbersThey agree with your description of the problem
They have already paid for a workaround (a product, a service, their own time)They have never tried anything and are not bothered
Landing-page conversion to deposit or form above the pack's pass mark, from cold trafficConversion from friends, family and your own network
A named budget and a named decision-maker (B2B)An enthusiastic user who cannot buy

Go / no-go

  • Go to section 3 (business plan) and section 4 (start kit) when the kill question above is met by your own numbers, you have 15–20 written-up conversations, and at least one real signal from the left column per segment you plan to sell to. Only then does section 5 (Who to contact) apply.
  • Change the idea when the problem is real but the price, the buyer or the form factor in the pitch is wrong: the interviews will tell you which. Rewrite the pitch and run the fake door again; this is normal and costs a week.
  • Stop when the kill question fails on honest numbers, or when nobody you talked to has paid for a workaround. Pick another idea on this site; the boards in the start kit are not wasted, only unused.

The full worksheet, with how to define the segment and run the fake door, is in the playbook → validate demand.

3 · Business plan · estimates, not a forecast

Business plan

Problem & customer

The consumer question is "is this smell dangerous for my child?" and the honest answer is "measure it over a few days with the room closed and compare to 0.1 ppm". Nobody does that because the tools are wrong-sized: a €800–1,500 whole-flat lab analysis (one provider's range) is disproportionate; a €25 meter from a marketplace reads anything as formaldehyde. Reviews of popular consumer meters (e.g. Temtop M10, ~$115) complain that readings rise on alcohol and other gases — cross-sensitivity is the electrochemical sensor's known weakness, and cheap devices don't compensate.

  • Who pays (B2B, primary): the furniture or flooring retailer who wants to say "take this home for a week, see for yourself" — it's a sales tool and a complaint deflector. Real-estate agents and property managers at hand-over of a renovated flat (NL/DE: 'opleveringsrapport', 'Übergabeprotokoll'). Rental platforms for tools.
  • Who uses: the household, for 3–7 days, then returns it.
  • Who pays (B2C): parents, chemically sensitive people, new-build buyers; they find you via "Formaldehyd neue Möbel messen".

Market size (estimates — check)

  • TAM (devices): EU furniture/flooring stores ≈ 60k; real-estate and property-management offices ≈ 150k; at 3–5 loan units each → 600k–1M units → €120–200M theoretical; B2C: ~1M households per year renovating or moving with small children → at 5% conversion, 50k units/year (€10M) or 150k rental weeks (€4M).
  • SAM: DE/AT/CH/NL/BE/Nordics chains and independents that already lend tools or offer "healthy living" ranges ≈ 15k stores → €12M devices + recalibration €2M/year.
  • SOM (3 years): 150 stores × 5 units + 5k B2C + rental revenue → €1.6–2M. Year 1: 500–1,000 units.

Sources used: UBA/ex-Bundesgesundheitsamt guideline values (0.1 ppm / 0.1 mg/m³), Berliner Mieterverein and consumer-protection guidance, a commercial measurement provider's price ranges (€60–250 per room, €800–1,500 per flat), Temtop M10 listings and reviews. Store counts: estimates — verify.

Competition (2 searches)

AlternativePrice (est.)Why we still win
Do nothing / "air it out and see if the headache goes" (what consumer advisers actually say)€0No number, no reassurance, no documentation at hand-over
Passive sampler test kits (Bio-Check and similar), lab analysed€30–80 per testSingle point in time, days of waiting, no CO2/VOC context
Professional indoor-air measurement (sampler + lab)€150–250 per room; €800–1,500 per flatRight for disputes, disproportionate for "is my new wardrobe OK"
Consumer meters (Temtop M10 ~€110, many €20–60 marketplace devices)€20–120Known cross-sensitivity complaints, no calibration service, no report, you own a drifting sensor
Smart air monitors (air-Q, uHoo, Airthings)€200–500Permanent install, subscription-ish, HCHO only on the top models
Handheld pro meters (PCE and similar)€300–900Accurate-ish, no consumer UX, nobody lends them

Wedge: the only device designed to be lent — rugged, lanyard, one button, a 7-day report that names the guideline value and says "indicative", with annual recalibration built into the price — sold to the people who meet the worried customer at the till or the hand-over.

External market check

Competitors, demand signals and price comparables found by web search in November 2026. Sources are named as found and not linked; as researched November 2026 by web search; verify before relying on it. Verdicts are a reading of the evidence found, not a forecast.

Who / sourceWhat it isWhat it tells us
Extech VFM200 rentalProfessional meter rentalRental exists, professional channel
Kwipped PCE formaldehyde meterProfessional meter rentalSame
Wellbuild Lab IAQ test kit ($395–525/week)Lab-analysed home testWillingness to pay at a higher price

Verdict as researched: LIKELY. Main risk: No evidence yet that retailers want to run a loan-unit programme; that channel is the actual kill question and is unverified.

Product & value proposition

  • Handheld 130 × 55 × 25 mm, rubberised, lanyard, 2,000 mAh Li-ion, USB-C, 1.14"–1.5" display, one button. Runs 7 days on a charge at a 5-minute sample interval with a small fan pulse before each HCHO reading.
  • Sensors: electrochemical HCHO (ME2-CH2O-class), BME680-class gas/VOC + T/RH, NDIR CO2 (so people also learn that the room is simply under-ventilated — most of the time that's the real finding).
  • Compensation: T/RH compensation for the HCHO cell, VOC-interference flag (if VOC spikes while HCHO spikes, the report says "likely cross-sensitivity — ventilate and re-check"), sensor-age model with a replace-by date.
  • Report: BLE to a phone web app → 7-day PDF with the guideline lines (0.1 ppm HCHO; CO2 1,000/2,000 ppm), room notes, and "indicative — not a laboratory measurement" on every page.
  • Fleet mode for retailers: 5 units, charging dock, QR check-out, annual recalibration swap.
  • Pricing (estimates): B2C €199; retailer fleet of 5 + dock €899 + €149/year recalibration; rental €29/week via the retailer or a tool-rental platform.

Unit economics (estimates, EUR per unit)

Item1k5k
Electronics BOM (ESP32-C3/S3 module €2.5, electrochemical HCHO cell + AFE €9–12, BME680-class €6, NDIR CO2 module €9–14, display €3, Li-ion 2,000 mAh + charger/protection €4, micro-fan €1.5, PCB + passives €3.5)4235
PCBA assembly + test (gas-bench spot check, see below)5.03.4
Enclosure (two-shot rubberised, 2 tools ~€20k) + lanyard7.53.6
Packaging + USB-C cable + quick card2.41.8
Freight + duty to EU (air, Li-ion DG surcharge)4.52.4
Certification amortised (€40k: RED/BLE + EN 18031, EMC, safety, battery)40.08.0
Landed cost10154
D2C net price (€199 incl. 19% VAT → €167) less €9 fulfilment158158
Gross margin D2C€57 (36%)€104 (66%)
Retailer fleet net €150/unit ex VAT€49 (33%)€96 (64%)
Rental: €29/week, ~25 weeks/year utilisation → €725/year/unit before recalibrationpays back in <3 months—

The HCHO cell and the CO2 module are two-thirds of the BOM and both drift; the recalibration service is not an upsell, it is how the product stays honest.

Go-to-market

First 100 customers: three furniture retailers (the kill question) — independent "ökologische Möbel"/natural-living stores and one regional kitchen or flooring chain — with 5 loan units each at the till for a month. Reach them via the trade press for furniture retail and a direct visit with a working prototype. In parallel: real-estate agents in one city with a hand-over kit, and 50 B2C units to parents via two German/Dutch parenting forums and a Reddit AMA on indoor air.

Scale: furniture and flooring chains (loan fleets as a "healthy living" marketing programme), property managers and new-build developers (hand-over kit), tool-rental platforms and DIY chains' rental counters, pharmacies with a home-health range (B2C), and online via "Formaldehyd messen" SEO. Keep the lab-measurement providers as partners: when the report shows >0.1 ppm, the PDF recommends a professional measurement.

12-month plan

  • Q1: kill question (3 retailers, 15 loan units built from StickC-Plus + sensor boards), compensation algorithm v1 against a reference instrument, report PDF v1, wording reviewed by a lawyer.
  • Q2: own PCB, rubberised housing (SLA), 50 EVT units in 10 stores and 20 households, calibration jig with a reference HCHO source, pre-compliance.
  • Q3: DVT, certification (RED/BLE, EMC, safety, battery), pilot batch 100, fleet dock, recalibration process live.
  • Q4: production 1,000, B2C launch, rental-platform partnership, Nordic/Benelux retailers.

Team: founder (retail sales, content), 1 embedded engineer (ESP-IDF, sensor front ends, BLE), part-time chemist/measurement engineer (calibration, cross-sensitivity, reference comparisons — do not skip this person), part-time web developer (report app), contract ID/ME for the housing.

Funding to 1,000 units (estimate): NRE €32k (PCB €5k, housing + tooling €22k, calibration bench €5k) + certification €40k + 9 months lean salaries €60k + 1,000 units at €61 landed €61k = €193k, less first-year sales to retailers/B2C (~€110k) → €85k net. Route: retailer fleet deposits, a consumer-health or indoor-air innovation grant, a €50k angel; crowdfunding for the B2C wave once the retailer data proves the report resonates.

Top risks

  • Technical — sensor accuracy and drift. Electrochemical HCHO cells cross-react (alcohol, some VOCs), drift with humidity and age (2–3 years). Mitigation: T/RH compensation, VOC-interference flag, replace-by date, annual recalibration, and the word "indicative" everywhere. Validate against a reference instrument from day one.
  • Legal — someone makes a health decision on your number. Mitigation: wellness/indicative wording, no health claims, the PDF recommends a professional measurement above the guideline; lawyer-reviewed disclaimer; no "safe/unsafe" language — show the guideline line and the number.
  • Market — retailers don't want a device that might tell their customer the wardrobe emits. Mitigation: position it as "measure before and after, learn to ventilate" and as proof for low-emission (Blauer Engel-class) ranges; target stores that already sell low-emission products.
  • Regulatory — Li-ion: Battery Regulation (removability by 2027 for portable batteries — design a user-replaceable cell now), UN 38.3, DG shipping.
  • Supply — HCHO cells and NDIR modules come from a handful of vendors with 8–12-week lead times. Mitigation: qualify two cells (the two boards in the catalogue use different sensors — good), buy a year of cells once the compensation model is tuned to them.
4 · Start kit · boards, BOM, build plan, certification

Start kit

Boards to start from

BoardLinkWhat it contributesFiles (catalogue)Licence note
甲醛传感器 (OSHWHub, ME2-CH2O)gongbans.com/db/oshwhub-me2-ch2o.htmlOpen electrochemical formaldehyde sensor board — the HCHO analogue front end to learn fromschematic, pcbOSHWHub project licence — check before commercial derivation
BME680气体传感器 (OSHWHub)gongbans.com/db/oshwhub-bme680.htmlOpen BME680 gas/VOC + T/RH board — compensation inputs and the VOC channelschematic, pcbOSHWHub project licence — check
Seeed Grove-HCHO Sensorgongbans.com/db/seeed-grove-hcho-sensor.htmlAlternative HCHO sensor reference (second cell type)schematicSeeed open-hardware terms; check the wiki licence
M5Stack StickC-Plus (K016-P)gongbans.com/db/m5stack-stickc-plus.htmlHandheld display + battery + ESP32 for the 15 loan-unit pilotenclosure/structure files only; electronics not publishedOff-the-shelf; use as bought

Block diagram

[HCHO electrochemical cell + AFE] --ADC--> |
[BME680-class VOC/T/RH] ---------I2C-----> | [ESP32-C3/S3] --> compensation (T/RH, VOC flag, age) --> 7-day log (flash)
[NDIR CO2 module] ----------------UART---> |      |-- BLE --> phone web app --> 7-day PDF report
[micro-fan pulse] <--GPIO------------------+      |-- display (number, trend, guideline marker), 1 button
[Li-ion 2,000 mAh, USB-C charge, protection] --> 3.3 V

Engineering gap: the compensation and ageing model (this is the product); a calibration bench with a reference HCHO generator or certified instrument; a rugged, lendable housing with a fan path that doesn't clog; a replace-by-date and recalibration workflow; fleet dock/check-out for retailers; and the report wording.

Starter BOM (estimates)

PartEst. unit costNotes
Electrochemical HCHO cell (ME2-CH2O / ZE08-class or equivalent)€8–112–3 vendors; 8–12 wk lead; shelf life — buy to plan
Low-noise AFE (TIA op-amp, ADC)€1.5Multi-source
BME680 / BME688€6Single vendor (Bosch); widely stocked
NDIR CO2 module (SCD4x-class photoacoustic or small NDIR)€9–142–3 vendors
ESP32-C3-MINI or S3 module€2.5Multi-source
1.14"–1.5" IPS display€3
Li-ion 2,000 mAh pouch/18650 with protection, user-replaceable€3.5Battery Regulation: design for replacement
Micro-fan 20 mm€1.5
Two-shot housing + lanyard€3.6 at 5kTooling €20k

Firmware/software starting point

  • ESP-IDF; Bosch BSEC library for BME680/688 (closed binary, free licence for products — read the terms) or the open BME680 driver for raw values.
  • Sensirion's embedded drivers for SCD4x on GitHub if you pick that CO2 module.
  • Web Bluetooth-based phone app (no app-store dependency) for the report; any server-side PDF library.
  • For the HCHO front end, the open OSHWHub board's schematic is your reference; the compensation model you write yourself with your measurement engineer.

12-week build plan

WeeksGateExit criteria
1–2Validate3 furniture retailers agree to put 5 loan units at the till for a month; 15 units built from StickC-Plus + sensor boards; first 10 households borrow one. Fewer than 3 stores or <40% of offered units borrowed: stop or move to the real-estate channel.
3–5Works-likeCompensation v1: within ±30% of a reference instrument between 0.03 and 0.3 ppm at 40–70% RH; VOC-interference flag works with an alcohol test; 7-day log + PDF v1; 20 borrower reports collected with a 5-question survey.
6–8Looks-like + EVTOwn PCB v1, SLA rubberised housing with fan path, 50 units in 10 stores; battery life ≥7 days verified; EMC pre-scan.
9–10DVT + pre-compliancePCB v2, tooled-part samples, RED/EMC/safety pre-test, UN 38.3 for the cell, EN 18031 checklist, lawyer-approved report wording.
11–12Pilot batch100 units from a CM with gas-bench spot checks (10%), golden sample, fleet dock prototype, recalibration SOP, first retailer invoices.

Certification checklist (EU)

  • CE / RED: BLE → EN 300 328, EN 301 489-1/-17, EN 62311; safety EN 62368-1 (Li-ion, charging).
  • RED delegated act — EN 18031-1 and -2: applies (BLE + internet via the phone app; -2 because the report contains room/location notes that may be personal data). Keep data on the device and in the user's phone; no account required.
  • CRA: reporting since September 2026, full December 2027; signed firmware, SBOM, disclosure.
  • Battery Regulation (2023/1542) + UN 38.3: Li-ion → labelling, removability/replaceability design, DG shipping; register as battery producer where required.
  • RoHS, REACH, WEEE, packaging registration.
  • GDPR: report data stays on the phone; if you add cloud storage, DPIA-lite and consent.
  • Not a measuring instrument under MID; not a medical device — keep claims to "indicative indoor-air information"; no health or diagnosis language, otherwise MDR territory.
  • Estimated test costs: RED/BLE €8–10k, EMC €4k, safety with battery €5k, UN 38.3 (if a custom pack) €3k, EN 18031-1/-2 €15–18k, documentation €2k. Budget €40k.

Validation toolkit

  • Kill question: will 3 furniture retailers put 5 loan units each at the till for a month, and do customers actually borrow them? Cheapest experiment: 15 units from StickC-Plus + the two sensor boards in a printed shell (~€60 each), a laminated till card, a paper check-out sheet. Cost ≈ €1,000 and 3 store visits.
  • 5-question interview (store manager): 1) How often does a customer ask about smell, emissions or "is this safe for the nursery"? 2) What do you say today, and does it close or lose the sale? 3) Do you lend anything today (tools, samples)? How does it come back? 4) If a borrowed meter showed a high value in a customer's home, what would you want the device to say? 5) Would you pay €899 for a 5-unit fleet with yearly recalibration — who decides?
  • Landing page: headline "New furniture, new floor, new flat? Know what you're breathing — in a week." Bullets: "Formaldehyde, VOC and CO2 logged for 7 days, with the official guideline value on the chart"; "Borrow it at your furniture store or rent it for €29 — return it when you're done"; "Indicative, honest, recalibrated every year".
  • Pass threshold: 3 stores × 5 units placed; ≥60% of units borrowed at least once in the month; 10 B2C pre-orders at €199 from the first 50 reports shared.

First production checklist

  • Samples: 15 pilot (dev-kit based), 50 EVT, 100 pilot; keep two per revision with gas-bench records.
  • Golden sample: gas-bench response at two HCHO concentrations, CO2 at 400/1,000 ppm, 7-day battery log, signed.
  • DFM review: fan path and membrane, cell seating and venting, battery door (replaceable), rubber over-mould adhesion, lanyard anchor strength.
  • MOQ talk: HCHO cells 1k (check shelf life!), CO2 modules 500–1k, PCBA 500, tooling at 1k shots.
  • QC/AQL: level II, AQL 1.0/2.5; 100% functional + BLE; 10% gas-bench spot check; 100% charging test.
  • Packaging: battery labelling, UN 38.3 summary, DG-compliant outer carton.
  • Incoterms: FOB Shenzhen with a DG-capable forwarder; or ship cells separately and insert in the EU.
5 · Who to contact · from gongban.db

Who to contact

On file: 2 board publishers (Seeed Studio and M5Stack). Only useful once section 2 (validate demand) has passed. Everything below comes from gongban.db, the directory behind this site. It names the companies that publish the boards this idea is built from, the manufacturers on file, and directory entries in the same product category. None of it is a verified supplier relationship for this specific idea: nobody has quoted it yet. Company websites only; no personal contacts are published.

Board publishers (direct)

  • Seeed Studio (矽递科技(深圳)有限公司, seeedstudio.com) — community / maker brand; 183 boards in the catalogue; files via Seeed Studio wiki catalog · github.com/Seeed-Studio/wiki-documents. Directory entry: IoT module + open hardware OEM: XIAO ESP32S3; Grove modules; LoRa gateway; Jetson carrier; OEM PCBA. Boards used here: Seeed Grove-HCHO Sensor (alternative HCHO sensor reference). What to ask for: sample units of the SKUs above, unit pricing at 100 / 500 / 1,000, whether a customised variant is possible (and its NRE and MOQ), and the module's radio test reports if any.
  • M5Stack — community / maker brand; 274 boards in the catalogue; files via M5Stack M5_Hardware repo · github.com/m5stack/M5_Hardware. Boards used here: M5Stack StickC-Plus (K016-P) (handheld display + battery for the prototype). What to ask for: sample units of the SKUs above, unit pricing at 100 / 500 / 1,000, whether a customised variant is possible (and its NRE and MOQ), and the module's radio test reports if any.

Open-hardware boards without a company behind them

  • OSHWHub community designs — community projects on OSHWHub 立创开源硬件平台 (JLC open hardware platform) · oshwhub.com . The author is an individual, not a supplier, and author handles are not published here. Fabricate from the files through a PCBA house (below) and check each project's licence first. Boards used here: 甲醛传感器 (open electrochemical formaldehyde sensor board); BME680气体传感器 (open BME680 gas/VOC + T/RH board).

Manufacturing (PCBA / EMS) on file

  • Kingbrother / King Brother Technology · global.kingbrother.com/ — PCB fab + EMS; see the Kingbrother SOM page on this site.
  • Foxlink (SZ) (正崴精密工业(深圳)有限公司) · foxconn.com — PCBA + cable assembly EMS: Cable assembly; PCBA; connector; OEM for major electronics brands.

MOQ and landed cost

gongban.db holds no MOQ, unit-price or tariff data for these companies, so none is shown. Get the numbers from the quote (the e-mail below asks for them) and run them through the landed-cost worksheet in the playbook. The starter BOM in the start kit section is an estimate, not a quote.

Outreach e-mail, ready to send

Fill in the [brackets], keep it short, and send it to the sales or "contact us" address on the company's own website. The Chinese version is the same letter; sending both in one mail is normal. How to read the reply: playbook → the first quote.

A. To a board publisher — samples and volume price (send to the sales / "contact us" address on the Seeed Studio and M5Stack websites)

A. 中文版

B. To a PCBA / EMS house — quote from the open design files (send to Kingbrother, Foxlink or any assembler you vet; see the playbook)

B. 中文版

6 · Next steps · this week

Next steps (this week)

  1. Order 3 StickC-Plus, 3 of each HCHO sensor board, 3 BME680 boards and a CO2 module; build one logger and put it next to a new piece of flat-pack furniture with the door closed for 48 hours.
  2. Visit two furniture stores with a "healthy living" range and ask the five questions; ask for a one-month loan-unit trial.
  3. Find a reference instrument you can borrow or rent (a university lab or a measurement provider) and schedule a comparison day; write the compensation-model plan with a measurement engineer.
Get this built

Want this built?

Get sourcing and manufacturing help from a team in Shenzhen and Europe.

Never built hardware? Start with the zero-experience founder playbook: samples, the first quote, CE/FCC, customs, logistics and the kill question, in order. Board facts come from the catalogue; everything else in this pack is an estimate.

Get this built →

Start pack new-flat-air-check · written by the GONGBANS inventor from the public catalogue and public sources. Concept generated by the GONGBANS inventor from the public catalogue, then expanded into a start pack. Not a product, not validated; every number (market, BOM, price, effort, certification cost) is a rough estimate to be checked, not a quote. Check each board's licence before commercial use. Not legal, tax or investment advice. Idea page · Download as Markdown · All 50 start packs →